R Remote Version 2 Users Guide 6
Set on the R series units
When using R Remote to operate an R series unit, set the DIP switches and [UNIT ID] rotary switch of
the unit, taking note of the following settings.
Set the UNIT ID in the range of 1 to 24 (hexadecimal 18). R Remote will not detect units with a
setting of 0 or 25 or higher. (For details on converting between decimal and hexadecimal, refer to
"Decimal/hexadecimal conversion table.")
Set the DIP switches to the following combinations. Put DIP switches 5 and 6 in the upward
position.
UNIT ID
Settings
Switch
UNIT ID ranging from 0 to F
(1 up)
UNIT ID ranging from 10 to 1F
(1 down)
IP address
Specify the IP address that R Remote uses for control. This is the setting for control; it is different
than the IP address of the Dante network, so it will be different than the IP address specified on
the Dante Controller.
The first time that you connect an R series unit to your computer after purchasing it, set this to
something other than STATIC IP (MANUAL). If you want to use the STATIC IP (MANUAL)
setting, first specify the IP address from R Remote and then switch to STATIC IP (MANUAL).
Settings Switch
AUTO IP
(The Dante network automatically sets the IP
address to 169.254.xx.xx)
(2 and 3 up)
DHCP
(The IP address assigned by the DHCP server
will be used.)
(2 down, 3 up)
STATIC IP(AUTO)
(The IP address will be set to 192.168.0.xx (xx=
UNIT ID).)
(2 up, 3 down)
STATIC IP(MANUAL)
(Set the IP address to the value specified by R
Remote)
(2 and 3 down)
If the network consists only of Dante devices and R Remote, we recommend that you use the AUTO IP setting.
If you are connecting to an existing network, select DHCP as needed.