Service manual

Fig. 3 Fig. 4
[A]: Bind Head Screw A3.0X6 MFZN2BL (VP156600)
[350]: Bind Head Screw A3.0X6 MFZN2BL (VP156600)
<Left Side View>
(DB-SREV1)
CNV
[A] [A][350] [350]
Printed side
CNV
CPU
1 2
3 4
5
CN123CN123
CN119CN119
CN122CN122
CN118CN118
6. Re-attach the SREV1 Top Cover
Replace the fourteen (14) fixing screws marked [850].
The top cover can then be Replaced. (Fig. 1)
7. Checking that the DB-SREV1 (CNV) Circuit
Board is Working Correctly
If the DB-SREV1 (CNV) circuit board is working correctly,
when the SREV1 is turned on the two rows of INPUT and
OUTPUT front panel indicators light up alternately in a
streaming pattern from left to right. If the indicators do not
light up like this, the DB-SREV1 (CNV) circuit board is not
working correctly, in which case you should check that it's
installed in accordance with these instructions.
8. Execute Test Program
Execute test program No. 5 in Section 5-2 and check if
operation is normal. (Refer to page 42.)
Fig. 5
(DB-SREV1)
3 4 6
CN2CN2 CN3CN3 CN1CN1
CNV
SREV1
18
4. CNV Circuit Board Installation
Reinstall the previously removed CNV circuit board,
remembering to replace the two (2) internal fixing screws
marked [360] and two (2) external fixing screws marked
[350]. (Fig. 2, 3)
Reconnect the two cable connectors and the power supply
connector. (Table 1)
5.
DB-SREV1 (CNV) Circuit Board Installation
5-1 Cut and remove the cable fastener holding the power supply
cable intended for the DB-SREV1(CNV) circuit board.
5-2 Install the DB-SREV1 (CNV) circuit board above the
existing CNV circuit board, secure it by using two (2)
internal fixing screws marked [B] and two (2) external
fixing screws marked [A]. (Fig. 2, 3)
5-3 Connect the two cable connectors and the power supply
connector, as shown in Figure 5. (Table 1)
1
2
3
4
5
6
MFA30100
MFA30100
MFA30140
MFA30140
(V6513200)
(V6513200)
CPU-CN122 CNV-CN2
CPU-CN123 CNV-CN3
CPU-CN118
DB-SREV1(CNV)-CN2
CPU-CN119
DB-SREV1(CNV)-CN3
Power Supply Unit-CN3
CNV-CN1
Power Supply Unit-CN4
DB-SREV1(CNV)-CN1
30P/L=100mm
30P/L=100mm
30P/L=140mm
30P/L=140mm
10P
10P
DESTINATION REMERKS
PARTS NO
• Connector Assembly
* Connector assembly listed above are not available as service parts
except MFA30100 and MFA30140.
Table 1