User Manual

reface Data List
8
reface DX
Control Change
Transmitted and recognized Control Change Number and Value, when MIDI control is
on.
Parameter Base Address
Bulk Dump Block
“Top Address” indicates the top address of each block designated by bulk dump oper-
ation.
Byte Count shows the size of data in blocks from Model ID onward (up to but not
including the checksum).
The Block from the Bulk Header to the Bulk Footer of the Voice can be received
regardless their order.
They can be received even if all of them are not transmitted. They cannot be received
if the irrelevant Block is included.
To carry out VOICE bulk dump request, designate its corresponding BulkHeader
address.
MIDI PARAMETER CHANGE TABLE (SYSTEM)
Total Size = 32
MIDI Data Table
Control Change Number Control Value
Notes
Name No. Description Transmitted Recognized
ALGO (algorithm) 80 ALGO 1 0 0 – 11
ALGO 2 12 12 – 21
ALGO 3 23 22 – 32
ALGO 4 35 33 – 42
ALGO 5 46 43 – 53
ALGO 6 58 54 – 64
ALGO 7 69 65 – 74
ALGO 8 81 75 – 85
ALGO 9 92 86 – 95
ALGO 10 104 96 – 106
ALGO 11 115 107 – 116
ALGO 12 127 117 – 127
OP1 LEVEL (output level) 85 0 – 127 0 – 127
OP1 FB (feedback level) 86 0 – 127 0 – 127
OP1 FB (feedback type) 87 sawtooth 0 0 – 63
square 127 64 – 127
OP1 FREQ MODE 88 frequency/ratio (Ratio) 0 0 – 63
fixed freq/Hz (Fixed) 127 64 – 127
OP1 FREQ RATIO/FREQ
(coarse)
89 0 – 31 0 – 31
OP1 FREQ RATIO/FREQ
(fine)
90 0 – 99 0 – 99
OP2 LEVEL (output level) 102 0 – 127 0 – 127
OP2 FB (feedback level) 103 0 – 127 0 – 127
OP2 FB (feedback type) 104 sawtooth 0 0 – 63
square 127 64 – 127
OP2 FREQ MODE 105 frequency/ratio (Ratio) 0 0 – 63
fixed freq/Hz (Fixed) 127 64 – 127
OP2 FREQ RATIO/FREQ
(coarse)
106 0 – 31 0 – 31
OP2 FREQ RATIO/FREQ
(fine)
107 0 – 99 0 – 99
OP3 LEVEL (output level) 108 0 – 127 0 – 127
OP3 FB (feedback level) 109 0 – 127 0 – 127
OP3 FB (feedback type) 110 sawtooth 0 0 – 63
square 127 64 – 127
OP3 FREQ MODE 111 frequency/ratio (Ratio) 0 0 – 63
fixed freq/Hz (Fixed) 127 64 – 127
OP3 FREQ RATIO/FREQ
(coarse)
112 0 – 31 0 – 31
OP3 FREQ RATIO/FREQ
(fine)
113 0 – 99 0 – 99
OP4 LEVEL (output level) 114 0 – 127 0 – 127
OP4 FB (feedback level) 115 0 – 127 0 – 127
OP4 FB (feedback type) 116 sawtooth 0 0 – 63
square 127 64 – 127
OP4 FREQ MODE 117 frequency/ratio (Ratio) 0 0 – 63
fixed freq/Hz (Fixed) 127 64 – 127
OP4 FREQ RATIO/FREQ
(coarse)
118 0 – 31 0 – 31
OP4 FREQ RATIO/FREQ
(fine)
119 0 – 99 0 – 99
Parameter Block
DescriptionTop Address (hex)
High Mid Low
SYSTEM 00 00 00
VOICE COMMON 30 00 00
VOICE OPERATOR 31 op 00 op: operator number (00 – 03)
Parameter Block Description
Byte Count Top Address (hex)
Dec Hex High Mid Low
SYSTEM Common 36 24 00 00 00
VOICE Bulk Header 4 04 0E 0F 00
COMMON Voice Common 42 2A 30 00 00
Operator Operator 1
:
Operator 4
32 20 31 00
:
03
00
Bulk Footer 4 04 0F 0F 00
Address (hex)
Size
Data Range
(hex)
Parameter Name Description Notes
High Mid Low
00 00 00 1 00 – 0F, 7F MIDI transmit
channel (TR CH)
1 – 16, off
01 1 00 – 0F, 10 MIDI receive
channel (RV CH)
1 – 16, All
02 4 00 – 00
00 – 07
00 – 0F
00 – 0F
Master Tune -102.4 – +102.3 (cent)
1st bit 3-0 : bit 15- 12
2nd bit 3-0 : bit 11- 8
3rd bit 3-0 : bit 7- 4
4th bit 3-0 : bit 3- 0
06 1 00 – 01 Local Control
(CONTROL)
off, ON
07 1 34 – 4C Master Transpose -12 – +12 (semitones)
08 2 00 – 02
00 – 7F
Tempo MSB
Tempo LSB
30 – 300
1st bit 6-0 : bit 13-7
2nd bit 6-0 : bit 6-0
0A 1 00 – 3F LCD Contrast
(CONTRAST)
0 – 63
0B 1 00 – 01 Sustain Pedal
Select (SUSTAIN)
FC3, FC4/5
0C 1 00 – 01 Auto Power-Off
(AUTO P.OFF)
off, ON
0D 1 00 – 01 Speaker Output
(SP)
off, ON
0E 1 00 – 01 MIDI Control
(CONTROL)
off, ON
0F 1
reserved
10 1 reserved
11 1 reserved
12 1 reserved
13 1 reserved
14 1 reserved
15 1 reserved
16 1 reserved
17 1 reserved
18 1 reserved
19 1 reserved
1A 1 reserved
1B 1 reserved
1C 1 reserved
1D 1 reserved
1E 1 reserved
1F 1 reserved