If you want to use zoning to set the IP address, or want to connect to an existing network but use a static IP
address, choose STATIC IP (MANUAL) and use R Remote to set the IP address.
SECONDARY PORT
Settings
Switch
DAISY CHAIN
(4 up)
REDUNDANT
(4 down)
START UP MODE
Settings
Switch
REFRESH
(The unit starts up with part of the internal
memory initialized.
Initialization creates the following settings.
HA GAIN (-6 dB)
+48V (OFF)
HPF (OFF)
HPF FREQ (80Hz)
Gain Compensation (OFF))
(7 and 8 up)
RESUME
(The unit starts up using the settings assigned
prior to the most recent power off.)
(7 down, 8 up)
If a CL/QL series unit is not connected, we recommend that you set START UP MODE to RESUME. If this is set to
REFRESH, settings must be transmitted from R Remote each time the R series unit is restarted.
Connect the computer and R series units
Use an Ethernet cable to connect the computer and the R series units.
If you selected DAISY CHAIN in SECONDARY PORTon the above, connect the Dante connectors of
the R series units in a daisy chain to the computer.
If you selected REDUNDANT in SECONDARY PORTon the above, connect the computer to the
network switch that is connected to the Dante [PRIMARY] connector.
Power-on the R series units
Power-on the R series units. If you power-on before making
Settings on the R series units,” the
settings will not be applied.