User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
V5 Reference Manual
157
NOTE
• You can also change the effect type by recalling a library setting.
• Effect types “HQ.PITCH” and “FREEZE” can be used only in rack 1, 3, 5, or 7. Also, even if you
copy these two effect types, you will not be able to paste them to rack 2, 4, 6, or 8.
4 EFFECT CUE button
Cue-monitors the output of the currently-displayed effect. This Cue function is valid only
while this screen is displayed. The cue will be canceled automatically when you switch
to a different screen.
NOTE
If the Cue mode is set to MIX CUE, all channels for which the CUE key is turned on will be
monitored. However, only the output signal of the effect will be monitored if you turn on the
EFFECT CUE button. (The [CUE] keys that had been turned on until then will be temporarily
defeated.)
The cue monitoring does not support CUE B.
5 Special parameter field
Indicates special parameters that are specific to some effect types.
TEMPO
This field appears if a tempo-type or modulation-type effect is selected.
• MIDI CLK button
If you turn this button on, the BPM parameter of that
effect will be set to match the tempo of the MIDI timing
clock being input from the MIDI port.
PLAY/REC
This field appears if FREEZE is selected as the effect type.
• PLAY button/REC button
Enable you to record (sample) and play back when using
the freeze effect. For detailed operations, refer to “Using
the Freeze effect” (page 161).
SOLO
This field appears if M.BAND DYNA. or M.BAND COMP. is
selected as the effect type.
•HIGH/MID/LOW buttons
Allow only the selected frequency band to pass (multiple
selections are allowed).
• Gain reduction meters
Indicate the amount of gain reduction for each band.
Gain reduction meter
This field appears if Comp276/276S or Comp260/260S is
selected as the effect type.
• Gain reduction meters
Indicate the amount of gain reduction applied by the
compressor.
Type
This field is displayed when Equalizer601 is selected as the effect
type.
•Type
Select one of two equalizer types that feature different effects.
DRIVE emulates changes in frequency response of analog circuits,
creating a driven sound that enhances analog characteristics by adding some distortion.
CLEAN emulates changes in frequency response that are typical of analog circuits,
creating a clear non-distorted sound that is inherently digital.