User Manual

Table Of Contents
Scene memory
V5.8 Reference Manual
105
Using the Focus Recall function
“Focus Recall” is a function that lets you specify the parameters that will be updated when you
recall a scene. For example, it is convenient to use this if you want to recall only the input
channel settings of a certain scene.
NOTE
In contrast to Focus, the CL series console also features a “Recall Safe” function that enables you
to exclude specific channels and parameters from recall operations. However, while the Focus
Recall function is specified individually for each scene, the Recall Safe settings are applied to all
scenes.
NOTE
The FOCUS field enables you to make settings for the Focus function. The buttons in this field
correspond to the scene list shown on the left side of the SCENE LIST window.
Scenes for which Focus settings are made are indicated by a “FOCUS” indication in the STATUS
field of the SCENE LIST window.
You can use the Focus function in conjunction with the Recall Safe function. Channels or
parameters that are excluded from Recall operations by either Focus or Recall Safe will not be
recalled.
For FOCUS RECALL, the NAME parameter is included in the DCA indicator.
FOCUS RECALL window
Sets the parameters that will be recalled.
1 CLEAR ALL button/SET ALL button
Turns off or on all focus channel selections and global focus parameter settings.
2 Focus channel display field
Indicates the target channel for a Recall operation. The view of this field is the same as
that in the RECALL SAFE window.
3 SET BY SEL button
Turn on this button to add a channel by using the corresponding [SEL] key. To add
channels as the target, turn on this button, and then press the corresponding [SEL] keys
for the channels you want to add.
NOTE
In the case of the CL3/CL1, channels that do not exist on those models will not be shown.
STEP
1. Press the SCENE field in the Function Access Area.
2. Press the FOCUS tab at the bottom of the SCENE LIST window.
3. In the SCENE LIST window, press the SET button for the scene you want to set.
4. Follow the procedure starting with step 3 in the “Using the Recall Safe function
(page 82) to make settings.
5. If you want to cancel the specified restrictions so that all parameters will be subject
to recall, turn on the ALL button.
6. Recall a scene for which you have made Focus Recall settings.
SCENE field SCENE LIST window
3
8
6
5
9
1
2
4
7
0
All parameters are affected by Recall on these
Some parameters are affected by Recall on
Recall has been canceled on these channels.