User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Main fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
V5.8 Reference Manual
172
Also, when this button is off, the COMPRESSOR field for the selected band turns gray.
You can adjust each parameter even when this button is off.
C FLAVOUR button
Switches the type of compressor between accurate VCA operation and natural OPTO
operation.
D HARMONICS button
Switches on/off the analog circuitry that emulates musical overtones.
Using the graphic EQ, parametric EQ, effect, and
Premium Rack libraries
GEQ/PEQ library
Use the “GEQ library” or “PEQ library” to store and recall GEQ and PEQ settings. All GEQ
and PEQ units used in the CL series console can use this GEQ library or PEQ library.
Although are two types, 31BandGEQ and Flex15GEQ in the GEQ library, you are free to recall
items between differing types. However, only 31BandGEQ settings that use less than fifteen
bands can be recalled to a Flex15GEQ.
200 items can be recalled from the library. Number 000 is a read-only preset, and the
remaining library numbers can be freely read or written.
To recall an item from the GEQ library, press the LIBRARY button located at the top of the
GEQ EDIT window.
Similarly, to recall an item from the PEQ library, press the LIBRARY button located at the top
of the PEQ EDIT window.
NOTE
• Store and recall operations are performed on individual GEQ units. For one rack, you can store
and recall two Flex15GEQ or 8BandPEQ units independently as A and B.
• To access the GEQ EDIT window or the PEQ EDIT window, press the rack container in the GEQ
field.
Effect library
Use the “Effect library” to store and recall effect settings. 199 items can be recalled from the
effect library. Library items 1-27 are read-only presets, and correspond to effect types 1-27
respectively. The remaining library numbers can be freely read or written.
To recall an item from the effect library, press the LIBRARY button located at the top of the
EFFECT EDIT window.
Premium Rack library
You can use the Premium Rack library to store and recall Premium Rack settings. The library
contains 101 items (from #000 through #100). Item #000 is a preset. All library items other
than #000 can be freely read and written.
To recall an item from the Premium Rack library, press the LIBRARY button located at the top
of the window for the corresponding type.