User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Main fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Setup
V5.8 Reference Manual
219
Setup
About the SETUP screen
The SETUP screen enables you to set various parameters that apply to the entire CL console.
To access the SETUP screen, press the SETUP button in the Function Access Area. The
screen contains the following items.
CURRENT USER field
This field enables you to make various user-related settings.
1 USER SETUP button
Press this button to open the USER SETUP window, in which you can make various
settings for each user.
2 CURRENT USER button
Press this button to open the LOG IN window, in which you can switch log-in users.
3 COMMENT EDIT button
Press this button to open the COMMENT EDIT window, in which you can enter
comments that will be displayed in the comment area.
4 PASSWORD CHANGE button
Press this button to open the PASSWORD CHANGE window, in which you can change
the password.
5 SAVE KEY button
Press this button to open the SAVE KEY window, in which you can overwrite (save) the
user authentication key (page 226).
STORAGE field
This field enables you to create, save, or load a user authentication key.
6 CREATE USER KEY button
Press this button to open the CREATE USER KEY window, in which you can create a new
user authentication key.
7 SAVE/LOAD button
Press this button to open the SAVE/LOAD window, in which you can save or load user
authentication keys and console files.
SYSTEM SETUP field
This field enables you to make various settings that globally apply to the CL series console.
8 +48V ACTIVE button
Switches the console’s +48V ACTIVE phantom power on or off. When this button is off,
+48V phantom power for all the head amps turns off.
NOTE
If this button is off, phantom power will not be supplied even if the +48V button of each channel
is on.
9 WORD CLOCK/SLOT SETUP button
Press this button to open the WORD CLOCK/SLOT SETUP window, in which you can
make word clock settings and various settings for each slot.
0 CASCADE button
Press this button to open the CASCADE window, in which you can make patch settings
for cascade connections.
A OUTPUT PORT button
Press this button to open the OUTPUT PORT window, in which you can make output
port settings.
B MIDI/GPI button
Press this button to open the MIDI/GPI window, in which you can make MIDI and GPI-
related settings.
C DANTE SETUP button
Press this button to open the DANTE SETUP window. This window enables you to make
various audio network settings (console ID setting; SECONDARY PORT functionality
setting; audio bit rate; latency setting; DANTE device ID and device type settings for
devices controlled via the I/O RACK screen).