User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
V5 Reference Manual
169
1 INPUT ADJUST
Used to adjust the input gain. However, the output gain is linked to change in the
opposite direction, to prevent changes in pass-through volume (the volume when
COMP IN and LIMIT IN are off). For example, if INPUT ADJUST is +5dB, the input gain
is +5dB and the output gain is -5dB.
See below for more information about how to use INPUT ADJUST.
• If the level of the input signal sent to effects is too low to reach the threshold, increase
the input gain.
• Adjust the sound quality by changing the input level sent to the input circuitry (audio
transformer and Class A amplifier).
INPUT ADJUST structure
2 LINK (STEREO mounting)
Stereo link on/off
3 COMP IN
Compressor on/off
4 COMP THRESHOLD
Compressor threshold. However, the changing value is linked to INPUT ADJUST.
5 COMP RECOVERY
Compressor release time. The release times for a1 (auto 1) and a2 (auto 2) change
automatically. a1: Changes automatically between 100 ms and 2 sec. a2: Changes
automatically between 50 ms and 5 sec.
6 COMP GAIN
Compressor make-up gain. Applied before the limiter.
7 COMP RATIO
Compressor ratio
8 METER SELECT (STEREO mounting)
Selects the signal source for the meter. You can select from IN (input level), GR (gain
reduction), and OUT (output level). When the source is switched, the design of the
meter also switches as follows: VU/GR/VU.
When “METER” is IN
When “METER” is GR
dBFSdBFS
COMP THRESHOLD LIMIT THRESHOLD
Buss Comp 369
COMPRESSOR/LIMITER SECTION
INPUT
CIRCUIT
OUTPUT
CIRCUIT
OUTPUT GAININPUT GAIN
INPUT ADJUST
COMPRESSOR LIMITER
OUT
OUT
IN IN
Since there are substantial changes in threshold, the changing display values are
linked. However, the internal conditions of the COMPRESSOR/LIMITER
SECTION do not actually change.
Linked in reverse
8
8