User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
I/O devices and external head amps
V5 Reference Manual
191
EXTERNAL HA window
Remotely control the external head amp. Display this window by pressing the virtual rack in
the I/O DEVICE screen (EXTERNAL HA page).
1 +48V MASTER
If an external HA is connected, the master phantom power on/off status is shown here.
(The on/off setting is made on the external HA unit itself.)
2 +48V button
These switch phantom power on/off for each channel.
3 GAIN knob
These indicate the gain of the external HA. If you press and select the GAIN knob, you
can make adjustments to gain using multifunction knobs 1-8. The level meter located
at the immediate right of the knob indicates the input level for the corresponding port.
4 FREQUENCY knob/HPF button
These controllers switch on or off the high-pass filter built into the external HA, and
adjust its cutoff frequency. If you press the FREQUENCY knob to select it, you will be able
to adjust it using the corresponding multifunction knob.
5 Rack select tabs
These tabs switch the rack that is displayed in the EXTERNAL HA window.
NOTE
• If you connect an additional AD8HR, the setting for this AD8HR will be used.
These knobs and buttons are displayed in the EXTERNAL HA window even if an AD8HR is not
connected, allowing you to create and store a scene even while the AD8HR is not connected.
• Error messages related to the SB168-ES will not be displayed. In addition, you will be unable
to set the EtherSound parameters. Use AVS-ESMonitor for these functions.
Remotely controlling an external HA from the input channels on a CL
series console
You will be able to use the external HA in the same way as the head amp on an I/O device or
on the CL console. For details on the GAIN/PATCH window, refer to “HA (head amp) settings”
(page 32).
2
3
5
1
4
STEP
1. Use the Bank Select keys in the Centralogic section to access the OVERVIEW screen
that includes the channel for the head amp that you want to control.
2. Press the HA/PHASE field of the channel whose external HA you want to adjust.
3. Press the PATCH button in the GAIN/PATCH window, and select the input port
assigned to the external HA.
4. Remotely control the external head amp in the GAIN/PATCH window.
OVERVIEW
screen
GAIN/PATCH window