User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
MIDI
V5 Reference Manual
199
MIDI CONTROL CHANGE window
Display this window by pressing any event in the CONTROL CHANGE page. In this window,
you can specify the event assigned to each control number.
1 MODE field
Enables you to select the type of event.
2 PARAMETER 1/2 field
In conjunction with the MODE field, this field specifies the type of event.
3 OK button
Confirms the settings and closes the window.
NOTE
• The list shown is the same for all models of the CL series. For the CL3/CL1, the display will
indicate “Cannot Assign!” if you specify a parameter that does not exist on that model.
• If NRPN mode is selected as the control change transmission/reception mode, the settings in this
window are ignored.
• For details on the events that can be assigned to Control Changes, refer to the data list at the end
of this manual.
Using parameter changes to control parameters
On the CL series console, you can use a type of system exclusive messages called
“Parameter Changes” to control specific events (fader/knob operations, [ON] key on/off
operations, system and user settings, etc.) as an alternative to using Control Changes or
NRPN messages.
For details on the Parameter Changes that can be transmitted and received, refer to the data
list at the end of this manual.
NOTE
• Parameter changes include a “device number” that specifies the transmitting or receiving device.
The transmit (Tx) channel and receive (Rx) channel specified on the MIDI SETUP page are used
as the device number.
• Please be aware that if the device number included in the transmitted Parameter Change does
not match the device number of the receiving CL console, the message will be ignored.
• Do not turn Parameter Change and Control Change transmission/reception on at the same time.
Otherwise, a large amount of data will flood the MIDI port and may cause overflows or other
problems.
1
2
3
STEP
1. Connect the CL series console to an external device.
2. As described in “Basic MIDI settings” (page 192), select the ports and MIDI channels
(device number) that will be used to transmit/receive parameter changes.
3. Use the Tx button and Rx button of the PARAMETER CHANGE field in the MIDI
SETUP page to turn on parameter change transmission/reception.