User Manual

Table Of Contents
I/O devices and external head amps
Reference Manual
179
Connecting the CL series console to an SB168-ES
To remotely control the SB168-ES from the CL series console, install an MY16-ES64
EtherSound card in Slot 1 of the CL, then use an Ethernet cable to connect the CL to the
SB168-ES. This connection enables you to remotely control the SB168-ES from the CL series
console.
Alternatively, you can use a daisy chain or ring connection and install two MY16-EX
expansion cards in the slots on the CL unit to remotely control up to three SB168-ES units
simultaneously.
NOTE
Remote control data will be received and transmitted only at Slot 1 of the CL series console.
Daisy chain network
Ring connection
NOTE
Please refer to the SB168-ES Owner’s Manual for information on setting up the MY16-ES64/
MY16-EX cards and EtherSound network.
SB168-ES
SB168-ES
SB168-ES
MY16-
ES64
MY16-
EX
MY16-
EX
CL5
OUT
Audio signal
Remote signal
IN
OUT
IN
IN
OUT
SB168-ES
SB168-ES
SB168-ES
CL5
MY16-
ES64
MY16-
EX
MY16-
EX
Audio signal
Remote signal
OUT
IN
OUT
IN
IN
OUT
OUT