User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Monitor and Cue functions
V5 Reference Manual
124
CUE window
You can make detailed settings for the cue. This window will appear when you press the
INPUT/DCA/OUTPUT CUE field.
1 CUE MODE buttons
Select one of the following two cue modes:
• MIX CUE
All selected channels will be mixed and monitored.
•LAST CUE
Only most recently selected channel will be monitored.
NOTE
All cue selections will be cleared if you switch between MIX CUE mode and LAST CUE mode in
the CUE MODE section.
INPUT CUE field
This field enables you to make settings related to the input channel cue.
2 Cue point select button
Sets the cue point to PFL (immediately before fader), AFL (immediately after fader), or
POST PAN (immediately after PAN).
NOTE
Be aware that if you turn on the POST PAN button, you will be unable to monitor signals sent to
the MONO bus from an input channel in LCR mode.
3 PFL TRIM knob
Indicates the monitor levels when PFL is selected. You can adjust the level using the
multifunction knob.
You can adjust the monitor levels in the range of -30dB to +20dB.
DCA CUE field
This section enables you to make settings related to DCA cue.
4 Cue point select button
Sets the cue point for the DCA group to PRE PAN (immediately before PAN) or POST
PAN (immediately after PAN).
5 DCA TRIM knob
Indicates the monitor level of cue signals from a DCA group. You can adjust the level
using the multifunction knob.
You can adjust the monitor levels in the range of -30dB to +20dB.
6 UNITY button
Turn on this button to monitor signals at the same volume level that was obtained when
the master level for each DCA group was set to 0 dB (unity gain).
OUTPUT CUE field
This section enables you to make settings related to output channel cue.
7 Cue point select button
Sets the cue point for the output channel to PFL (immediately before fader) or AFL
(immediately after fader).
8 PFL TRIM knob
Indicates the monitor levels when PFL is selected. You can adjust the level using the
multifunction knob.
You can adjust the monitor levels in the range of -30dB to +20dB.
Meter field
9
ACTIVE CUE indicator
Lights to indicate the type of cue currently being monitored (input: blue, DCA: yellow,
output: orange).
0 CLEAR CUE button
Cancels all cue selections simultaneously.
NOTE
If you press the CUE meter in the Function Access Area, all cue selections will be cleared.
A Meter section
This field indicates the output level of the cue L/R channels.
F
E
G
I
BA74
D >965 8
12
3
C
H