User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
V5 Reference Manual
165
3 TIME CONSTANT knob
Switches the attack and release time. The settings are as follows.
4 THRESHOLD knob
Adjusts the level at which enhancement begins. Signals below the THRESHOLD are
attenuated.
5 PROCESS ACTIVE indicator
This indicator is lit when the input signal exceeds the THRESHOLD. Adjust the
THRESHOLD so that this indicator is lit when the primary audio source is being input,
and unlit during periods of silence or between phrases.
6 DEPTH knob
Adjusts the amount of attenuation for signals below the THRESHOLD.
U76
U76 is a processor that emulates a popular vintage compressor used in a wide range of
situations. This processor does not provide the threshold parameter that is found on
conventional compressors. Instead, the intensity of compression is determined by the
balance between the input gain and the output gain. The “All mode” setting for the RATIO
parameter allows you to create a heavily-compressed sound that is typical of this model. It
produces an aggressive tonal character with a rich addition of overtones.
1 INPUT knob
Adjusts the input level. As the input level gets higher, more compression is applied.
2 ATTACK knob
Adjusts the compressor’s attack time. Fully rotate the knob clockwise to set the fastest
attack time.
3 RELEASE knob
Adjusts the compressor’s release time. Fully rotate the knob clockwise to set the fastest
release time.
4 RATIO switch buttons
Use these five buttons to set the compression ratio.
A button with a higher number will raise the compression ratio more. Pressing the ALL
button selects All mode, in which the RATIO will become high, and sharp compression
with a faster release time will be applied, creating substantially-distorted aggressive
sound.
5 METER switch buttons
Switch the meter display.
• GR.................Indicates the amount of gain reduction applied by the compressor.
• +4/+8.............Each meter uses -18 dB as the reference level of the output signal, and
indicates “0VU” for the value of the reference level added by +4 dB or
+8 dB.
• OFF...............Turns off the meter display.
6 OUTPUT knob
Adjusts the output level.
If you have adjusted the amount of gain reduction by changing the INPUT knob, the
level of audible volume will also change. In this case, use the OUTPUT knob to adjust
the volume level.
RMS Mode PEAK Mode
A: 50 ms
B: 100 ms
C: 200 ms
D: 750 ms
E 1.5 s
F: 3 s
Attack: fixed at 20 ms
Release: A: 20 ms
B: 200 ms
C: 1 s
D: 2 s
E: 5 s
F: 30 s