User Manual

*[ERR T12] TWINLANe T V B
OP IP
Yellow (lit steadily)
An error has occurred with
the optical transceiver
module on the HY256-TL/
HY256-TL-SMF.
T: Temperature, V: Voltage, B:
Bias current, OP: Output
Power, IP: Input Power
• Make sure that the cable is
securely inserted.
• Use a commercially-
available cleaning tool for
fiber optics to clean both
ends of the cable and the
connectors on the card.
• Change to a different cable.
If the solutions above do not
resolve the issue, have the
unit checked by an
authorized technician,
although the problem will not
affect operation of the unit.
Please contact your Yamaha
dealer.
*[ERR T0#] CONSOLE NETWK
WRONG LOOP
Red (flashing)
Ethernet cable is not
connected properly. A
number sign (#) indicates the
error description.
4: Signal is looped back to the
unit itself (IN-OUT).
5: Input connectors are
connected to each other (IN-
IN).
6: Output connectors are
connected to each other
(OUT-OUT).
Check the cable connection.
*[ERR T08] CONSOLE NETWK
OPEN LOOP
Yellow (lit steadily)
Ethernet cable is not
connected properly. The
Console network loop is not
closed.
Check the cable connection.
*[ERR W01] BNC UNLOCK Red (flashing)
The unit is unable to lock to
the word clock that is being
input from the WORD CLOCK
IN connector (if the WORD
CLOCK IN has been selected
as the clock source).
Check the external device
that is supplying the word
clock.
*[ERR W02] DATA CORRUPT
TRY RE-SYNC
Red (flashing)
Mix data inside the unit has
been corrupted. The loading
of a file or data syncing might
have been interrupted due to
power outage.
Try data syncing again by
transmitting data from the
control surface.
*[ERR P01] POWER A OFF Yellow (lit steadily)
Power is not supplied from
power supply unit A.
Make sure that the power
switch on power supply unit A
is turned on, and that the
power cord is connected to
the unit and power supply
unit A.
1012
Messages > DSP Messages