User Manual

Level indicator
Gray: –∞
Green: <–18 dB
Yellow: –18 dB≤, ≤0 dB
Red: 0 dB<
EQ field
This field indicates the approximate response of the EQ. Press this field to open the HPF/EQ (1CH) popup
window, in which you can set the HPF, LPF and EQ. This field will be grayed out on channels for which the EQ
is disabled.
DYNAMICS 1/2 field
This field displays the threshold value, meter, and abbreviated dynamics processor type for Dynamics 1/2.
Press this field to open the DYNAMICS 1/2 (1CH) popup window. If GATE is selected as the dynamics type, an
indicator appears, indicating the gate status. If the dynamics processor is any type other than GATE, the
abbreviated type name will appear in this field, and the threshold setting will be indicated as a horizontal
line on the meter. For information on the abbreviated name and GATE indicators that are displayed, see
(DYNAMICS1/2 popup window).
SEND field
This field displays the send level, output bus name, and send on/off status for 12 buses.
160