User Manual

b
Clock status display
Indicates the status of synchronization with the master clock for each clock source. Each indicator is explained
below.
(
LOCK (light blue)
Indicates that a clock synchronized with the selected clock source is being input. If an external device is connected
to the corresponding connector or slot, it indicates that a clock is being input or output properly between that
device and the RIVAGE PM series. If the sampling frequency is close, this status may be displayed even if not
synchronized.
(
LOCK, BUT NOT SYNC’ED (yellow)
A valid clock is being input, but is not synchronized with the selected clock source. If an external device is
connected to the corresponding connector, it indicates that a clock is not being input or output properly between
that device and the RIVAGE PM series.
(
UNLOCK (red)
A valid clock is not being input. If an external device is connected to the corresponding connector, a clock will not
be input or output properly between that device and the RIVAGE PM series.
(
UNKNOWN (black)
This indicates that the clock status cannot be detected because no external device is connected or because there
is no valid clock input. You will be able to select this connector/slot, but successful synchronization cannot occur
until a valid connection is established.
NOTE
(
If the indicator for the port selected as the clock source has turned light blue, and the clock frequency appears in the upper left of
the MASTER CLOCK SELECT field, this indicates that the RIVAGE PM series is operating correctly with the new clock.
(
If the indicator for the selected clock does not turn light blue, make sure that the external device is correctly connected, and that
the external device is set to transmit clock data.
(
Noise may occur at the output jacks when the word clock setting is changed. To protect your speaker system, be sure to turn down
the power amp volume before changing the word clock setting.
c
Master clock select buttons
Use the buttons to select the clock source that you want to use as the word clock master from the following options:
(
INT 44.1 kHz
(
INT 48 kHz
(
INT 88.2 kHz
(
INT 96 kHz
The internal clock of the DSP engine (sampling rate: 96 kHz, 88.2 kHz, 48 kHz or 44.1 kHz) will be the clock source.
(
WORD CLOCK IN
The word clock supplied from the WORD CLOCK IN jack on the rear panel of the master DSP engine will be used as
the clock source.
(
FROM HY SLOT1-4 (or FROM HY SLOT1-3 on the CSD-R7)
The word clock supplied from the HY card slot located on the rear panel of the DSP engine is used as the clock
source.
NOTE
If the unit is initialized to the factory default status, the word clock default value will be set to 96 kHz.
d
TWINLANe network setting buttons
Use these buttons to specify operation (master/slave) within the TWINLANe network.
294
System Setup > WORD CLOCK popup window (Master mode)