Using the GEQ popup window for the inserted GEQ
1
32
4
Press the rack container of the rack (which contains an inserted GEQ) to open the GEQ popup window.
GEQ popup window
a
RTA button
If this button is on, a semi-opaque frequency analysis graph of the input signal (immediately after EQ) will be
superimposed on top of the EQ frequency response graph.
b
PEAK HOLD
If this button is on, the analyzed frequency response graph will hold the peak level indication.
c
HOLD button
If this button is on, the frequency response graph will indicate and hold the result of the frequency analysis.
d
BALLISTICS field
(
BALLISTICS button
If this button is on, you will be able to add rate of decay to the analyzed frequency response graph.
(
FAST/SLOW switch button
Switches the decay rate of graph rendering (FAST/SLOW).
455