User Manual

Controlling GAIN/SILK via the OVERVIEW screen
NOTE
(
The PAD will be switched on or off internally when the HA gain is adjusted between +11 dB and +12 dB.
(
Keep in mind that noise may be generated when using phantom power if there is a difference between the Hot and Cold output
impedance of an external device connected to the input jack.
(
The ANALOG GAIN knob and +48V button are enabled for the input jacks of an I/O rack and the OMNI IN jacks of the control surface.
(
HA settings can also be made in the SYSTEM CONFIG parameter settings screen (“Editing the internal parameters of each
component”(p.260)).
1 Press the [VIEW] key to access the OVERVIEW screen.
2 Select the channel that you want to operate.
3 Press the ANALOG GAIN knob or the SILK field.
ANALOG GAIN knob in
the OVERVIEW screen
SILK field in the
OVERVIEW screen
The “GAIN/SILK popup window”(p.470) appears.
4 Use the on-screen buttons and screen encoders to make HA settings.
5 Edit the SILK settings as needed.
6 Perform the same operations for other input channels as desired.
If you are viewing the GAIN/SILK popup window, you can also use the [SEL] keys to switch the
channel for editing.
7 When you finish making settings, press the X symbol in the upper right of the
window.
469