User Manual

[How INPUT ADJUST works]
Buss Comp 369
COMPRESSOR/LIMITTER SECTION
INPUT ADJUST
INPUT GAIN OUTPUT GAIN
INPUT
CIRCUIT
OUTPUT
CIRCUIT
COMP THRESHOLD LIMIT THRESHOLD
IN
COMPRESSOR
OUT
LIMITTER
IN
OUT
dBFS
.
dBFS
.
Practically, since the threshold changes, the indicated value will change in
tandem.
However, the internal status of the COMPRESSOR/LIMITER section will not
change.
Inversely change in tandem
Practically, since the threshold changes, the indicated value will change in tandem. However, the internal status of the ,
COMPRESSOR/LIMITER section will not change.
b
LINK switch (for Stereo mount)
Turns the stereo link on/off
c
COMP IN switch
Turns the compressor on/off.
d
COMP THRESHOLD knob
Adjusts the threshold of the compressor. Note that the value changes in tandem with the INPUT ADJUST
setting.
e
COMP RECOVERY knob
Adjusts the release time of the compressor. For a1 (auto 1) and a2 (auto 2), the release time changes
automatically.
a1: automatically changes in the range of 100 ms to 2sec.
a2: automatically changes in the range of 50 ms to 5 sec.
699
Plug-ins > Controlling the Buss Comp 369 plug-in parameters