User Manual

d
Time code source
Selects the source of the time code that will be used.
(
OFF..................................Time code is not received.
(
INTERNAL ....................The time code internally generated by the control surface is used.
(
TIMECODE IN..............The time code that is input from the TC IN connector of the DSP engine is used.
(
MTC CONSOLE ..........The MIDI time code that is input from the MIDI connector of the control surface is used.
(
MTC ENGINE...............The MIDI time code that is input from the MIDI connector of the DSP engine is used.
e
Frame Rate
Selects one of the following as the frame rate of the time code that is used.
(
30....................................30 frames/second (non-drop)
(
30D.................................30 frames/second (drop frame)
(
29.97.............................29.97 frames/second (non-drop)
(
29.97D..........................29.97 frames/second (drop frame)
(
25....................................25 frames/second
(
24....................................24 frames/second
f
Offset time / Start time
If INTERNAL is selected as the time code, this specifies the start time of the internal time code. If any other time code
source is selected, this specifies the offset value. The offset value is the interval by which time code received from an
external source is adjusted forward or backward when recalling a scene.
g
List
This area displays the events added to the event list. The following items can be displayed in the list.
(
No. ...................................This column displays event numbers.
(
TRIGGER.......................This column displays the type of trigger that executes an event.
(
EVENT............................This column displays the description of an event to be executed.
You can use the SHOW COMMENTS button to specify whether you want to show comments for a scene.
h
INSERT field
Adds a new event to the event list.
(
MANUAL button...........The event is recalled by using the DIRECT button or an assigned USER DEFINED key.
(
INTERVAL button.........The event is recalled when the specified length of time elapses after the previous event was
recalled.
(
TIMECODE button........The event is recalled when time code reaches the specified time.
i
AUTO CAPTURE button
This allows an event to be registered in real time according to the time code. When you turn this button on, time code
starts, and when a scene or library item is recalled using the SCENE MEMORY section, the corresponding scene
number and time code location are captured and added as a new event.
j
MOVE field
(
UP button
Moves the currently selected event up step-by-step in the event list.
(
DOWN button
Moves the currently selected event down step-by-step in the event list.
815