User Manual

4 Select the tab for the desired fader calibration operation.
If the MOTOR DRIVE calibration tab is selected:
For the specified faders in the Channel Strip section and Master section, the motorized fader
movement will be automatically calibrated.
5 Press the [SEL] key for each fader that you want to calibrate.
Faders for which a problem was detected in the fader settings at start-up will already be
selected.
6 Press the START button.
The system starts optimizing the movement of the motorized faders. The corresponding [SEL]
keys will flash during calibration. To cancel in the middle of calibration, press the STOP
button. When optimization of the motorized fader movement is complete, the [SEL] keys will
go dark.
7 When calibration is complete, press the FINISH button.
The calibration values will be saved in internal memory. If the [SEL] key lights and the color
bar becomes red, calibration has failed. Press the START button to perform calibration again.
958
Maintenance > Adjusting the faders