Adjusting the detection point of the touch screen panels
(CS-R5 CS-R3)
Follow the steps below to correctly align the positions of the LCD display and the touch screen panels.
1 Press the SETUP button on the menu bar to access the SETUP screen.
2 Press the MAINTENANCE button to access the MAINTENANCE popup window.
This screen includes several pages, which you can switch between using the tabs located at
the top of the screen.
3 Press the TOUCH CALIB tab.
The TOUCH SCREEN CALIBRATION screen will appear, enabling you to calibrate the touch
screen panels.
4 Select the bay for which the touch screen panel will be adjusted, and press the
button. CS-R3 has BAY C only.
The calibration values will begin.
5 A cross-shaped cursor will appear in the screen a total of 16 times. Press each
location at which it appears.