FAQ
Q. Can two RIVAGE PM Editor apps be connected to one NETWORK [PC]
connector?
A. Yes, they can. Use a network switch to connect two computers in which RIVAGE PM Editor
is installed. Please make sure to only connect devices to the network switch that are able to
support the network connector.
Q. When connecting multiple Dante networks with different physical
connections to multiple HY144-D cards, can all the networks be set with their
link-local address?
A. No, they cannot. Each Dante network must have a unique subnet (network address).
Please see Example 2 of the "3-3 Connection Examples" section to make the settings
properly.
Q. The DANTE SETUP options in SYSTEM CONFIG are grayed out and
cannot be edited. How can I make the settings?
A. It seems that your network is not set up properly. Please check the settings again. To
connect multiple Dante networks with different physical connections, see Example 2 of the
"3-3 Connection Examples " section to make the settings properly.
Q. Is it possible to segment a switch into a Dante network and a control
network using a VLAN and connect the two networks to one switch?
A. Yes, it is. Make sure to configure the VLANs properly to prevent the two networks from
accidentally connecting to each other. Also, connect the two switches via the trunk ports. Use
switches with an appropriate uplink speed that’s able to accommodate the bandwidth being
used.