User Manual

RIVAGE PM Series Firmware Update Guide 7
When your computer is connected to the CSD-R7, updates will be applied to all RPio622/RPio222 devices
connected to the Main I/O Network.
NOTICE Do not connect the network connectors of multiple devices to the same network switch. These connectors are connected
to each other via a network in a system. Normal communication may not be possible within the system since a loop is created by
connecting to a network switch.
NOTE
Be sure to assign a unique Unit ID to each device.
To use a Sub I/O Network (supported by the DSP-R10/DSP-RX/DSP-RX-EX), the firmware version of all devices
connected to the Sub I/O Network must be updated to V2.0 or later. If the device in use is using a firmware version
earlier than V2.0, either connect it directly to your computer, or connect it to the Main I/O Network and update the
firmware to V2.0 or later.
Do not simultaneously update the CSD-R7 (update using a USB flash device) and the RPio622/RPio222 (update via
a network) that are connected to the same network. To update these devices simultaneously, remove the CSD-R7
from the network before performing the update.
The console cannot be updated via a network. Use a USB flash drive to perform the update.