User Manual

RIVAGE PM Series OSC Specications Version 1.0.2
3
1. Setup
1.3. Conguring the Remote Controller
RIVAGE PM can be controlled from an external device via Ethernet (NETWORK terminal).
The settings on the remote controller side for each connection are as follows -
IP Address: Specify the DSP ENGINE IP SETTING IP address of the RIVAGE PM system to
be controlled.
IP Port No.: UDP 49900
1.4. Conguration Examples
Below are several example commands set using an OSC Controller, in this case with the
QLab application. Qlab does not require type tags to be added to the command. A type tag
may be required depending on the OSC Controller application, please check this for the OSC
controller to be used.
1.4.1. Parameter setting Examples
Set the fader level of input channel 1 to -∞
Category
Parameter
Description
<Action>
<OSC address> <X> X name
<Y>
range
Y
name
<type
tag>
type
tag
<value> value
comment
min max
scaling
unit
Input
Channel
Input Channel
Fader Level
set
MIXER:
Current/InCh/Fader/Level
1 -
InputChannelNum
Input
Channel
1 - i: int -32768 1000 100 dB -Innity -
+10dB
Format: /yosc:req/<Action>/<OSC address>/<X>/<Y> <value>
Command: /yosc:req/set/MIXER:Current/InCh/Fader/Level/1/1 -32768
Set the channel color of MIX channel 1 to pink
Category
Parameter
Description
<Action>
<OSC address> <X>
X
name
<Y>
range
Y
name
<type
tag>
type
tag
<value> value
comment
min max scaling unit
Mix Bus Mix Channel
Channel Color
set
MIXER:
Current/Mix/Label/Color
1 -
MixChannelNum
Mix
Bus
1 - s: string - - - - See
Table 2
Format: /yosc:req/<Action>/<OSC address>/<X>/<Y> <value>
Command: /yosc:req/set/MIXER:Current/Mix/Label/Color/1/1 Pink
Remark: The " " in <Value> is not required in Qlab.
1.4.2. Snapshot setting example
Recall SCENE 5.00
Category
Parameter
Description
<Action> <OSC address> <X>
X
name
<Y>
range
Y
name
<type
tag>
type
tag
<value> value
comment
min max scaling unit
Scene Recall Scene ssrecallt_ex MIXER:Lib/Scene - - - - s: string "1.00" "999.99" - - -
Format: /yosc:req/<Action> <OSC address> <value>
Command: /yosc:req/ssrecallt_ex MIXER:Lib/Scene "5.00"
1.1. Connection Procedure
Connect the remote controller to the network terminal of each device as shown below. The
device to be controlled is specied by its IP address. Connect RIVAGE PM to the Network PC
terminal (computer connection terminal for external control) of either the Console or the DSP
Engine. Up to 10 remote controllers can be connected to one RIVAGE PM system.
Remote
Controller
Network
Switch
Ethernet
EthernetEthernet
Ethernet
RIVAGE PM Editor
Network PC terminal
(computer connection terminal for external control)
ConsoleDSP Engine
1.2. RIVAGE PM Conguration
DSP Engine IP address setting:
Uses the same IP address as MonitorMix and Immersive Sound connections.
Open the following NETWORK window from SETUP in the menu bar.
Set the IP address and subnet mask in DSP ENGINE IP SETTING.
After completing the settings, turn on the ENABLE button.