User Manual

Digital Input/Output Characteristics
*2: Use graded index multi-mode optical fiber cables with a core diameter of 62.5 m/
cladding diameter of 125 m, or a core diameter of 50 m/cladding diameter of
125 m.
*3: Use 75 ohm impedance coaxial cables.
*4: 75Ω terminated
Temperature Range
Dimensions (W x H x D) and Net Weight:
125 mm x 37 mm x 207 mm, 0.45 kg
Included Accessories:
Owner’s Manual, Card installation instructions leaflet
Terminal Format Audio Data
length
Level Connector
OPTICAL 1 IN/
OPTICAL 2 IN
*2
AES10-2008
(MADI)
24-bit -31 – -14 dBm SC
OPTICAL 1 OUT/
OPTICAL 2 OUT
*2
-23.5 – -14 dBm SC
COAXIAL 1 IN/
COAXIAL 2 IN
*3
0.15 – 0.6 Vp-p BNC
COAXIAL 1 OUT/
COAXIAL 2 OUT
*3
0.3 – 0.6 Vp-p BNC
WCLK IN FOR
SRC
——TTL
*4
BNC
Conditions Min. Typ. Max. Unit
Temperature
Range
Operating Temperature Range 0 40 °C
Storage Temperature Range -20 60 °C