User Manual

Table Of Contents
[SYSTEM] Indicators Meaning Possible Solution
Light Light
You changed the positions of the device
setting DIP switches or rotary switch, or
changed the Dante settings from Dante
Controller. Therefore, the positions of
the device setting DIP switches do not
match the actual Dante settings.
If the Device Lock setting was enabled
from Dante Controller, disable the
setting, or check the device setting DIP
switch positions, and set them to
accommodate the current situation.
Warning Messages
The indicators will light and/or flash as shown until the cause is resolved. If the green [SYNC] indicator is
unlit, the unit’s clock is unconfirmed.
[SYSNC] Indicators Meaning Possible Solution
Flash
The word clock is not set correctly.
Set the clock master and sampling
frequency correctly on the Rio-native
device or in Dante Controller.
Flash x2
Dante Network circuit is broken.
Make sure that the Ethernet cables are
not removed or short-circuited.
Flash x3
Other Dante-compatible devices cannot
be found due to an incorrectly-wired
Dante Network.
Make sure that the Ethernet cables are
connected correctly.
If the green indicator is flashing, the unit is the clock master. If the green indicator is lit, the unit is the clock
slave and the clock is synchronized.
290