CONSOLE NETWORK OUT/IN connectors
These RJ-45 connectors allow the unit to be connected to a Console Network(*) in a ring topology via Ethernet cables
(CAT5e or higher recommended).
Console Network
A DSP engine is equipped with a special control surface terminal to connect to a control surface. A network
created by the control surface and a DSP engine is called a “Console Network.”
NOTE
Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure that the metal parts of the plugs
are electrically connected to the STP cable's shield by conductive tape or comparable means. The use of Ethernet cables with
Neutrik etherCON CAT5 compatible RJ-45 plugs is recommended. Standard RJ-45 plugs can also be used. Cable length can
span up to 100 meters between devices. Maximum practical distance may vary depending on the cable used.
l
ERR indicators
This indicator lights up or flashes red if an error occurs. In such an event, please contact your Yamaha dealer.
m
LINK indicator
This indicator flashes or lights up, depending on the network status.
Green (flashing)
The unit is preparing to connect to the console network. If it continues flashing, the system is not
functioning properly. If the problem persists after you take the following actions, please contact your
Yamaha dealer.
Make sure that the cables are connected properly.
Make sure that the cables are securely inserted (locked in).
Turn the power to the RIVAGE PM series system off and then on.
Change to a different cable.
Green (lit
steadily)
The unit is connected to the console network properly.
n
TX/RX indicators
The appropriate indicator flashes green when data is transmitted from (TX) or received at (RX) the TO ENGINE OUT/IN
connectors.
o
LINK/ACT indicator
This indicator flashes or lights up green, depending on the connection status.
p
NETWORK
connector
This RJ-45 connector allows the unit to be connected to a computer or network device via an Ethernet cable (CAT5e
or higher recommended).
NOTE
Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure that the metal parts of the plugs
are electrically connected to the STP cable’s shield by conductive tape or comparable means. The use of Ethernet cables with
Neutrik etherCON CAT5 compatible RJ-45 plugs is recommended. Standard RJ-45 plugs can also be used. Cable length can
span up to 100 meters between devices. Maximum practical distance may vary depending on the cable used.