User Manual

CONTENTS
Displaying a patch conflict between DSP engines
9 RIVAGE PM series V2.2 Supplemental Manual
Message regarding a stolen patch Patch screen
OUTPUT patch screen
1 TWINLANe network (main/sub) assignment display
The number of patches is shown in red for the output channels that are not assigned to the
TWINLANe network. (The left half represents main, and the right half represents sub.)
2 Display for incomplete patches
If the rectangular indicator representing the number of assignments of the target port is
displayed in yellow, the port is available but the patch to that port is not yet active (Not Active).
To make it active, you must remove the patch, and then make the patch again.
If the rectangular indicator representing the number of assignments of the target port is
displayed in red, the port is currently being patched (Used) from another DSP engine or
device. Alternatively, the port may be unavailable (Not Available) because the number of
available ports is limited due to the setting on the card. Please be aware that removing a patch
may inadvertently remove other patches that are being used by different engines.
NOTE
If a patch conflict occurs, the PORT IDENTIFY function of the I/O rack will be disabled. In this case,
the following message will appear in yellow at the bottom of the screen.
“PORT IDENTIFY not available! This channel is not currently patched to an Output Port.
1
2