Rear Panel
) AC IN connectors
Use these sockets to connect the supplied power
cords. First connect the AC power cords to this unit,
and then insert the power cord plugs into AC outlets.
Insert the cord plugs all the way until they lock in
place securely. The supplied AC power cords feature a
Vlock mechanism via a latch, which prevents the
power cords from disconnecting accidentally.
NOTE
Be sure to connect the power cords to power supply units
A and B. In this way, if one of the power supply units
malfunctions, the other unit will supply power to continue
the operation.
CAUTION
Be sure to turn off the power to the unit before connecting
or disconnecting the power cord.
To disconnect the power
cord, remove it while
pressing the latch on the
plug.
! Vent
This unit is equipped with cooling fans. These vents
let warm air out from the unit. Please make sure that
you do not block the vents with any object.
@ [FAULT OUTPUT] connectors
This Euroblock connector is used to send an
indication of abnormality to the outside of the unit.
Connect a lamp or buzzer here. The NC and C
terminals will short-circuit if the unit is operating
normally. The NO and C terminals will short-circuit
if an abnormality is detected.
NOTE
The NO and C terminals will also short-circuit if you
intentionally turn off the power to the unit, just as they will if
a problem with power occurs.
@ #
^
)
!
$ %
Example: Using LEDs to indicate the RPio222’s
normal/faulty status
• Normal state
• Faulty state
C
NC
NO
C
NC
NO