HY144-D-SRC Firmware Update Guide 13
11. Click [Start].
A pop-up is displayed confirming that you
wish to proceed.
12. Click [OK] to start the recovery.
Dante Firmware Update Manager will display
Processing Safe Recovery,” and then Safe
Recovery Done.” when the device(s) are
recovered.
13. Exit the Dante Firmware Update Manager,
and wait for two minutes before turning
off the power to the device to which the
HY144-D-SRC is installed.
After recovery, the Dante module will be
restarted. If you power-off the device to
which the HY144-D-SRC is installed before
restart is completed, the data of the Dante
module will be corrupted, and you will have
to perform the recovery once again. Start
Dante Controller, and if the device name is
shown in black, it is safe to turn off the
power.
14. The correct Dante firmware now needs to
be loaded.
After recovery, the Dante firmware will not
be the latest version. To update to the latest
firmware, perform steps 2 through 10 of
Updating the firmware.”
The recovery and the firmware update are now
complete.