User Manual

RIVAGE PM7 System Setup Guide
36
3. Align both edges of the card with the guide
rails inside the slot, and then insert the card
into the slot.
Push the card all the way into the slot so that the
connector at the end of the card is correctly inserted
into the connector inside the slot.
4. Fasten the card using the screws attached to
the card.
If the card is not fastened securely, component failure
or malfunction may occur.
NOTE
Use a tool, such as a screwdriver, to tighten the screws
securely and affix the card.
The unit’s card slots are designed so that all cards will be
installed without any gap between them to improve
shielding quality.
If the screws are tightened incorrectly or insufficiently, the
shielding quality will fall short. Also, you might have
difficulty in installing additional cards.
Setting the Unit ID
You must set a unique ID for each device connected to the
same network so that the system will identify the devices
correctly. You can identify the Unit ID for each device on
the LCD of the corresponding device.
Setting the Unit ID on the I/O rack
1. Switch on power A and B on the I/O rack for
which you want to set the Unit ID.
The Unit ID of the corresponding device will appear
on the LCD.
I/O rack: M1-8, S1-8*
* The CSD-R7 will not recognize devices with IDs S1-8.
Be sure to use IDs M1-8.
2. Press the [MENU] key.
The menu screen will appear.
3. Use the [U]/[D] keys to move the cursor to
Unit ID.
4. Press the [ENTER] key.
The Unit ID setup screen will appear.
5.
Use the [
U
]/[
D
] keys to select a unique Unit ID.
6. Press the [ENTER] key to confirm the Unit ID
setting.
If you press the [MENU] key without confirming the
Unit ID beforehand, the unit will return to the top
screen.
Card