User Manual

RIVAGE PM7 System Setup Guide
48
General Specifications
At the time of measurement, all faders are set to nominal. Output impedance of the signal generator is 150Ω.
Frequency response
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz @20 Hz–20 kHz, reference to the nominal output level @1 kHz
Total harmonic distortion
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
* An 80kHz, 18 dB/octave low pass filter is used to measure total harmonic distortion.
Hum & noise
*2
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
Dynamic range
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
* An IHF-A filter is used to measure dynamic range.
Specifications
Inputs Outputs RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8 OMNI OUT 1-8 600Ω GAIN: +66 dB –0.8 0.0 0.5 dB
Inputs Outputs RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8 OMNI OUT 1-8 60 +4 dBu@20 Hz–20 kHz, GAIN: +66 dB 0.12 %
OMNI IN 1-8 OMNI OUT 1-8 60 +4 dBu@20 Hz–20 kHz, GAIN: –6 dB 0.05 %
Internal OSC OMNI OUT 1-8 60 Full scale output @1 kHz 0.02 %
Internal OSC PHONES
Full scale output @1 kHz,
phones level control: max.
0.2 %
Inputs Outputs RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8 OMNI OUT 1-8
600Ω
Rs= 150Ω, GAIN: +66 dB
Master fader at nominal level and one
Ch fader at nominal level.
–128
EIN
*1
*1. EIN stands for Equivalent Input Noise.
*2. An IHF-A filter is used to measure hum & noise level.
dBu
–62 dBu
OMNI IN 1-8 OMNI OUT 1-8
600Ω
Rs= 150Ω, GAIN: –6 dB
Master fader at nominal level and one
Ch fader at nominal level.
–90 -85 dBu
All Inputs OMNI OUT 1-8
600Ω
Rs= 150Ω, GAIN: –6 dB
Master fader at nominal level and all
OMNI IN1-8 in faders at nominal level.
-76 dBu
OMNI OUT 1-8 60 Residual output noise, ST master off. –92 dBu
PHONES
Residual output noise, phones level
control min.
–88 dBu
Inputs Outputs RL Conditions Min. Typ. Max. Unit
OMNI IN 1-8 OMNI OUT 1-8 600Ω AD + DA, GAIN: –6 dB 114 dB
OMNI OUT 1-8 600Ω DA Converter 116 dB