RM Series (RM-CR/RM-CG/RM-TT/RM-WAP) Remote Control Protocol Specifications Version 2.0.0
10
3. Command Specifications
3.3.2. External control protocol run mode setting
2-3) Result and change notification character encoding setting
Command Option 1 Option 2 Description
scpmode encoding ascii ASCII encoding mode (default setting)
utf8 UTF-8 encoding mode
Response
Response string Description
OK scpmode encoding ascii ASCII encoding mode change complete
OK scpmode encoding utf8 UTF-8 encoding mode change complete
Example: Command: scpmode encoding utf8
Response: OK scpmode encoding utf8
Meaning: Change the result and change notification encoding code to UTF-8.
The encoding mode was changed to UTF-8.
2-4) Value notification mode setting
Command Option 1 Option 2 Description
scpmode valuetype raw Raw value mode (default setting)
normalized Normalized value mode
Response
Response string Description
OK scpmode valuetype raw Raw value mode change complete
OK scpmode valuetype normalized Normalized value mode change complete
Example: Command: scpmode valuetype normalized
Response: OK scpmode valuetype normalized
Meaning: Change parameter change notifications to normalized value mode.
Parameter change notifications were changed to normalized value mode.
2-5) Normalization resolution setting
Command Option 1 Option 2 Description
scpmode resolution (res) Resolution for normalized value notifications
(default setting = 1000)
Details: (res) = Resolution for normalized values
Response
Response string Description
OK scpmode resolution xxxx The resolution for normalized value notifications
Details: xxxx = Specified resolution * Specified resolution should be more than 100.
Example: Command: scpmode resolution 128
Response: OK scpmode resolution 128
Meaning: Set the resolution of normalized values for setn commands to 128.
The resolution of normalized values for setn commands was set to 128.