User Manual

Table Of Contents
RM Series (RM-CR/RM-CG/RM-TT) Remote Control Protocol Specications Version 1.1.0
55
8. Meter List
Applicable devices RM-CG
Usage example(s)
set
mtrstart RM:OutputPort 40
OK mtrstart RM:OutputPort
get
mtrstop RM:OutputPort
OK mtrstop RM:OutputPort
NOTIFY
NOTIFY mtr RM:OutputPort level 00 00
No. Case Action Address Meter Type Parameter
1 Request AEC reference signal level
notication start for input port
mtrstart RM:AecRefPort - 1 - 10000 meter transmittion
interval
1 10000 40
2 Request AEC reference signal level
notication stop for input port
mtrstop RM:AecRefPort - - - - - -
3 AEC reference signal level meter data for
input port
NOTIFY mtr RM:AecRefPort level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
4 Request input signal level notication start for
output port
mtrstart RM:OutputPort - 1 - 10000 meter transmittion
interval
1 10000 40
5 Request input signal level notication stop for
output port
mtrstop RM:OutputPort - - - - - -
6 Input signal level meter data for output port NOTIFY mtr RM:OutputPort level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
7 Request BeamDirection output start mtrstart RM:BeamDirection - 1 - 10000 meter transmittion
interval
1 10000 40
8 Request BeamDirection output stop mtrstop RM:BeamDirection - - - - - -
9 BeamDirection output data NOTIFY mtr RM:BeamDirection raw 0x00 - 0xB4 Beam Direction.
(Phi, Theta, HVAD Flg)
See data table
(Beam Direction)
0x00