User Manual

Table Of Contents
RM Series (RM-CR/RM-CG/RM-TT) Remote Control Protocol Specications Version 1.1.0
25
4. Command Sequence
4.2. Parameter sync sequence
Immediately after communication starts, the controller does not know anything about the most recent status of the controlled device.
Therefore, the controller must query all parameters that it plans to handle.
This also applies for when preset recall is executed, because the controller does not know how the device has changed.
Querying the most recent status of the controlled device or when a snapshot recall occurs
Remote controller Controlled device
Synced Synced
OK get RM:ExtMic_Fader/Ch/Level 0 0 -775
get RM:ExtMic_Fader/Ch/Level 0 0
Normally running
Connection detection
Normally running
Communication possible
Apply
OK get XXX/XXXXX/X/X/X/X/X X X
get XXX/XXXXX/X/X/X/X/X X X
Apply
OK get XXX/XXXXX/X/X/X/X/X X X
* Repeat get for all the necessary parameters.
get XXX/XXXXX/X/X/X/X/X X X
Apply
......
Executing this sequence synchronizes the status with the controlled device.
However, if the controller receives a change notication from the controlled device during this query sequence, the controller needs to
query again.