Front panel
1 (Power) indicator
2 (Status) indicator
NOTE:Occurrences of errors and severe errors are recorded in the alert log. For details, refer to page 43.
3 (Bluetooth
®
) button/indicator
4 RESET button
NOTE:Use a fine-tipped object such as an ejector pin to press the RESET button.
CONTROLS AND FUNCTIONS
Condition Power indicator Unit status
LAN cable plugged into Dante/PoE port Lit green Operating
LAN cable plugged into Dante/PoE port Flashes green Starting up
Flashes green quickly Supplied power insufficient
Condition Status indicator Unit status
Identify button in Web GUI clicked Flashes white Responding (to Identify function)
Updating firmware Flashes white quickly Firmware being updated
Flashes red Error occurring
Flashes red quickly Severe error occurring
Condition
Bluetooth indicator
Unit status
Making Bluetooth connection Brightly lit blue Bluetooth connection being made
Bluetooth in Web GUI enabled Dimly lit blue
Not connected
(although Bluetooth can be used)
Long-pressing the Bluetooth button/indicator (with
Bluetooth enabled) for 4 seconds or more
Flashes blue quickly Waiting for pairing/Pairing
Bluetooth in Web GUI not enabled Unlit Bluetooth cannot be used
Condition Status indicator Unit status
RESET button long-pressed for 4 seconds to less
than 8 seconds, then released
Flashes blue twice per second
(during long-pressing/resetting)
Network-related settings
Waiting for resetting/Resetting
RESET button long-pressed for 8 seconds to less
than 12 seconds, then released
Flashes blue three times per
second
(during long-pressing/resetting)
All settings
Waiting for resetting/Resetting
1
4
2 3