User Manual

Table Of Contents
RM Series (RM-CR/RM-CG/RM-TT) Remote Control Protocol Specications Version 1.1.0
53
8. Meter List
Applicable devices RM-CR
Usage example(s)
set
mtrstart RM:InputPort 40
OK mtrstart RM:InputPort
get
mtrstop RM:InputPort
OK mtrstop RM:InputPort
NOTIFY
NOTIFY mtr RM:InputPort level 28 28 2f 2e 00 00 …
No. Case Action Address Meter Type Parameter
1 Request input signal level notication start for
input port
mtrstart RM:InputPort - 1 - 10000 meter transmittion
interval
1 10000 40
2 Request input signal level notication stop for
input port
mtrstop RM:InputPort - - - - - -
3 Input signal level meter data for input port NOTIFY mtr RM:InputPort level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
4 Request input signal level notication start for
output port
mtrstart RM:OutputPort - 1 - 10000 meter transmittion
interval
1 10000 40
5 Request input signal level notication stop for
output port
mtrstop RM:OutputPort - - - - - -
6 Input signal level meter data for output port NOTIFY mtr RM:OutputPort level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
7 Request input signal level notication start for
FarEnd input CH
mtrstart RM:FeInPostFader - 1 - 10000 meter transmittion
interval
1 10000 40
8 Request input signal level notication stop for
FarEnd input CH
mtrstop RM:FeInPostFader - - - - - -
9 Input signal level meter data for FarEnd input
CH
NOTIFY mtr RM:FeInPostFader level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
10 Request input signal level notication start for
mic input CH
mtrstart RM:ExtMicPostFader - 1 - 10000 meter transmittion
interval
1 10000 40
11 Request input signal level notication stop for
mic input CH
mtrstop RM:ExtMicPostFader - - - - - -
12 Input signal level meter data for mic input CH NOTIFY mtr RM:ExtMicPostFader level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
13 Request input signal level notication start for
NearEnd input CH
mtrstart RM:NeInPostFader - 1 - 10000 meter transmittion
interval
1 10000 40
14 Request input signal level notication stop for
NearEnd input CH
mtrstop RM:NeInPostFader - - - - - -
15 Input signal level meter data for NearEnd input
CH
NOTIFY mtr RM:NeInPostFader level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
16 Request input signal level notication start for
FarEnd output CH
mtrstart RM:FeOutPostFader - 1 - 10000 meter transmittion
interval
1 10000 40
17 Request input signal level notication stop for
FarEnd output CH
mtrstop RM:FeOutPostFader - - - - - -
18 Input signal level meter data for FarEnd output
CH
NOTIFY mtr RM:FeOutPostFader level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
19 Request input signal level notication start for
NearEnd output CH
mtrstart RM:NeOutPostFader - 1 - 10000 meter transmittion
interval
1 10000 40
20 Request input signal level notication stop for
NearEnd output CH
mtrstop RM:NeOutPostFader - - - - - -
21 Input signal level meter data for NearEnd output
CH
NOTIFY mtr RM:NeOutPostFader level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
22 Request AGC RMS level notication start for
FarEnd input CH
mtrstart RM:FeInAGCIn - 1 - 10000 meter transmittion
interval
1 10000 40
23 Request AGC RMS level notication stop for
FarEnd input CH
mtrstop RM:FeInAGCIn - - - - - -
24 AGC RMS level meter data for FarEnd input CH NOTIFY mtr RM:FeInAGCIn level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
25 Request noise gate signal level notication start
for mic input CH
mtrstart RM:ExtMicGateOut - 1 - 10000 meter transmittion
interval
1 10000 40
26 Request noise gate signal level notication stop
for mic input CH
mtrstop RM:ExtMicGateOut - - - - - -
27 Noise gate signal level meter data for mic input
CH
NOTIFY mtr RM:ExtMicGateOut level 0x00 - 0x7F meter level.
(x Channel)
See data table
(Level Meter)
0x00
28 Request noise gate signal GR meter level
notication start for mic input CH
mtrstart RM:ExtMicGateGR - 1 - 10000 meter transmittion
interval
1 10000 40
29 Request noise gate signal GR meter level
notication stop for mic input CH
mtrstop RM:ExtMicGateGR - - - - - -
30 Noise gate signal GR meter data for mic input
CH
NOTIFY mtr RM:ExtMicGateGR gr 0x00 - 0x7F meter level.
(x Channel)
See data table
(GR Meter)
0x00
31 Request compressor signal level notication
start for mic input CH
mtrstart RM:ExtMicCompOut - 1 - 10000 meter transmittion
interval
1 10000 40
32 Request compressor signal level notication
stop for mic input CH