RM Series (RM-CR/RM-CG/RM-TT/RM-WAP) Remote Control Protocol Specications Version 1.2.0
59
8. Meter List
Meter List
Applicable devices RM-WAP-8
Usage example(s)
mtrstart
mtrstart RM:AecRefPort 40
OK mtrstart RM:AecRefPort
mtrstop
mtrstop RM:AecRefPort
OK mtrstop RM:AecRefPort
NOTIFY
NOTIFY mtr RM:AecRefPort 00 00 00 3f 54 22 …
No. Case Action Address Meter Type
Parameter
value min max default
1 Meter control Transmission request for AEC
reference input signal level
mtrstart RM:AecRefPort - 1 - 10000 meter transmittion
interval
1 10000 40
2 Meter control Stop request for AEC reference
input signal level
mtrstop RM:AecRefPort - - - - - -
3 Meter level notication for AEC reference
input signal
NOTIFY mtr RM:AecRefPort level 0x00 - 0x7F meter level.
(x Channel)
Refer to Data table/
level meter
0x00
4 Meter control Transmission request for output
signal
mtrstart RM:OutputPort - 1 - 10000 meter transmittion
interval
1 10000 40
5 Meter control Stop request for output signal mtrstop RM:OutputPort - - - - - -
6 Meter level notication for output signal NOTIFY mtr RM:OutputPort level 0x00 - 0x7F meter level.
(x Channel)
Refer to Data table/
level meter
0x00
7 Meter control Transmission request for
microphone RSSI level
mtrstart RM:MicLinkQualityRssi - 1 - 10000 meter transmittion
interval
1 10000 40
8 Meter control Stop request for microphone
RSSI level
mtrstop RM:MicLinkQualityRssi - - - - - -
9 Meter level notication for microphone RSSI
level
NOTIFY mtr RM:MicLinkQualityRssi dBm