User Manual
Table Of Contents
- RM Series (RM-CR/RM-CG/RM-TT/RM-WAP) Remote Control Protocol Specifications
- 0. Revision History
- 1. Setup
- 2. Command List
- 3. Command Specifications
- 4. Command Sequence
- 5. Meter Value
- 6. Parameter Value Details
- 7. Parameter List
- 8. Meter List
RM Series (RM-CR/RM-CG/RM-TT/RM-WAP) Remote Control Protocol Specications Version 1.2.0
6
2. Command List
2.1. Commands from a device sent to a remote controller
No. Notication details Reply from device Remarks
1-1 Device status change notication Device run mode notication NOTIFY devstatus runmode…
1-2 Device error status notication NOTIFY devstatus error…
1-3 Parameter change notication Parameter change notication raw value NOTIFY set…
Parameter change notication normalized value NOTIFY setn…
1-4 Meter information notication Meter information notication NOTIFY mtr…
1-5 Event processing change notication Alert notication NOTIFY event RM:Alert…
2.2. Commands for controlling a device
No. Notication details Reply from device Remarks
2-1 Device status query Device run mode query devstatus runmode
2-2 Device error status query devstatus error
2-3 RM-CR/CG external control protocol run mode
setting
Result and change notication character
encoding setting
scpmode encoding…
2-4 Value notication mode setting scpmode valuetype…
2-5 Normalization resolution setting scpmode resolution…
2-6 Keep alive activation setting scpmode keepalive…
2-7 Parameter query Raw value parameter query get…
2-8 Normalized value parameter query getn…
2-9 Parameter setting Raw value parameter setting set…
2-10 Normalized value parameter setting (*) setn…
2-11 Meter control Transmission request mtrstart…
2-12 Stop request mtrstop…
* When value is set "1023" (default:1000), control resolution becomes same as "Raw value" command.
See "6.1. Fader parameter" for the "Nomalised value" vs "Raw value" when the value is set "1023"
2.3. Extended commands
No. Notication details Reply from device Remarks
3-1 Product information query request RM-CR/CG external control protocol version
query
devinfo protocolver …
3-2 Parameter set version query devinfo paramsetver…
3-3 Firmware version query devinfo version …
3-4 Product name query devinfo productname …
3-5 Serial number query devinfo serialno …
3-6 Device category query devinfo category …
3-7 Device ID query devinfo deviceid…
3-8 Device label query devinfo devicename …
3-9 Product manufacture name query devinfo manufacturer …
3-10 Paramerer number query prmnum
3-11 Parameter structure query prminfo
3-12 Meter number query mtrnum
3-13 Meter structure query mtrinfo
3-14 Change target device Identify display mode identify