User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Main fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
V5.8 Reference Manual
145
Inserting a GEQ in a channel
This section explains how to insert a GEQ into the selected channel for use.
NOTE
• If you are using a stereo source, you can mount a Flex15GEQ, or mount two 31BandGEQ units
in adjacent odd-numbered/even-numbered racks. This will let you link the two GEQ units in a later
step.
• You can view the input and output levels of the GEQ in the rack in the GEQ field.
• For details on GEQ operations, refer to the following section “Using the 31BandGEQ” (page 146)
or “Using the Flex15GEQ” (page 147).
GEQ EDIT window
NOTE
The windows for the 31BandGEQ and the Flex15GEQ are nearly identical. However, the
Flex15GEQ individually displays two GEQ units (A and B) mounted in a single rack.
1 Rack select tabs
Switch among GEQ 1-8 or among GEQ 9-16. For a rack in which a Flex15GEQ is
mounted, the tabs will be split as xA and xB (x is the rack number).
2 INPUT button
Press this button to open the CH SELECT window, in which you can select the input
source of the rack. The operating procedure is the same as for the INPUT button in the
GEQ field.
3 OUTPUT button
Press this button to open the CH SELECT window, in which you can select the output
destination of the rack. The operating procedure is the same as for the OUTPUT button
in the GEQ field.
4 RACK LINK button
Press this button to open the RACK LINK window, in which you can link adjacent GEQ units.
In the case of a 31bandGEQ, the GEQ units in adjacent odd-numbered/even-numbered
racks will be linked. In the case of a Flex15GEQ, the GEQ(A) and GEQ(B) within the same
rack will be linked.
•GEQ x
y button ( “x” and “y” are the rack number, or the rack number and
alphabetical character A or B)
The parameters of “x” will be copied to “y,” and then linked.
•GEQ y
x button
The parameters of “y” will be copied to “x,” and then linked.
• RESET BOTH button
The parameters of both will be initialized, and then linked.
• CANCEL button
Cancels the link and closes the window.
NOTE
The RACK LINK button is shown only if linking is possible. When you link
GEQ units, a symbol will appear in the GEQ field to indicate the linked status.
5 FLAT button
Returns all bands of the currently-selected GEQ to 0 dB.
6 GEQ ON/OFF button
Switches the currently-selected GEQ on or off.
7 RTA button
Turn this button on to overlay a frequency response graph on the EQ.
STEP
1. Refer to steps 1-8 in “Virtual rack operations” (page 141) to mount a GEQ in a rack
and set its input source and output destination.
2. In the GEQ field, press the rack container in which you mounted the GEQ.
3. If you’re using a stereo source, press the RACK LINK button to link the two GEQ
units.
4. Press the GEQ ON/OFF button to turn the GEQ on.