User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Main fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Scene memory
V5.8 Reference Manual
97
SCENE LIST window
Here you can perform various scene-related operations. This window will appear when you
press the SCENE field.
1 Scene list
This area lists various data about the scenes stored in memory.
2 NO./TITLE buttons
Press these buttons to sort the listed scenes by number or title. Press the same button
repeatedly to toggle between ascending order and descending order.
3 Scene number
Indicates the scene number.
4 Scene title
Indicates the scene title. Press this button to display the SCENE TITLE EDIT window, in
which you can edit the title.
5 R symbol (READ ONLY)/Protect symbol
An “R” symbol is displayed for read-only scenes, and a protect (lock) icon is displayed for
write-protected scenes.
To enable/disable the scene protect setting, press the R symbol or protect symbol of the
selected scene. Pressing the protect (lock) symbol or the R (read-only) symbol
repeatedly will switch between displaying and hiding the corresponding symbol.
• Protect (lock) symbol
You will be unable to overwrite the scene.
• R (READ ONLY) symbol
Not only will the scene be protected, it will also not be overwritten by any file loaded
from a USB flash drive. You can only apply the protect setting to scenes with consecutive
scene numbers starting with scene #001.
•No symbol
No scene will be protected.
NOTE
The R symbol for scene number 000 cannot be disabled.
6 Current scene
The currently-selected scene (that is, the current scene) is highlighted in blue in the list.
If you press another scene number in the list, the list will scroll and that scene will
become the current scene.
7 SCENE SELECT knob
Use the multifunction knobs to select a scene. You can view the currently-selected scene
number immediately below the SCENE SELECT knob. You can select consecutive
multiple scenes by pressing and rotating the multifunction knob.
8 MULTI SELECT button
You can select consecutive multiple scenes by turning on this button and rotating the
multifunction knob.
9 LAST SCENE button
Selects the scene that was recalled most recently.
0 SCENE STORE button
Press this button to display the SCENE STORE window, which will enable you to assign
a name to a scene and store it.
A STORE UNDO button
Undoes the Store operation. This button is valid only immediately after you perform an
Overwrite-store operation.
NOTE
• The STORE UNDO button is available only immediately after overwrite-storing.
• You can also assign the function of the STORE UNDO button to a USER DEFINED key
(page 230).
B Page switching tabs
Switch the views for the right side of the SCENE LIST window.
C PREVIEW button
Press this to select PREVIEW mode, which allows you to view and edit the scene settings
in the display and the panel without affecting the signal processing of the current scene.
7
2
3
5
4
8
B9>A
6
C 1