I/O devices and external head amps
Reference Manual
174
NOTE
The indicator on the right side of the rack indicates the control status of the device.
You can perform the following operations from input channels patched to the target device:
Store/recall input channel library
Channel jobs (channel link, etc.)
HA controls at user level (only when operating HA from an input channel)
AG-DG LINK
NOTE
You cannot perform this operation on devices that do not support Gain Compensation.
I/O DEVICE HA window
Displayed when you press the rack in which the I/O device on the head amp side is mounted.
In this window, you can remotely control the head amp of the I/O device from the CL series
console by using the on-screen knobs and buttons or the multifunction knobs.
1 +48V MASTER
Indicates the on/off status of the I/O device’s master phantom power. (Switching this on
or off is performed on the I/O device itself.)
2 +48V button
These switch phantom power on/off for each channel.
3 GAIN knob
Indicates the gain of the head amp on the I/O device. To adjust the value, press the knob
to select it, and use the multifunction knobs. The level meter located at the immediate
right of the knob indicates the input level for the corresponding port.
4 GC button
Switches on or off the Gain Compensation function that maintains a consistent signal
level on the audio network.
5 FREQUENCY knob/HPF button
These controllers switch on or off the high-pass filter built into the head amp of the I/O
device, and adjust its cutoff frequency. If you press the FREQUENCY knob to select it,
you will be able to adjust it using the corresponding multifunction knob.
6 Displayed port switch tabs
These tabs switch the port that is displayed in the I/O DEVICE HA window.
7 GC ALL ON button/GC ALL OFF button
Switch Gain Compensation on or off for all input channels simultaneously.
8 GC indicator
Indicates the fixed gain value output to the audio network if the Gain Compensation
function is turned on.