User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/output characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Data List
22
MBC4
Automixer Parameters
Parameter Range Description
LOW CROSSOVER 20 to 500Hz Crossover frequency between the low and low mid bands
MID CROSSOVER 80 to 10kHz Crossover frequency between the low mid and high mid bands
HIGH CROSSOVER 1k to 15kHz
Crossover frequency between the low high mid and high
bands
LOW GAIN -18.0dB to 12.0dB Low band gain
LOW THRESHOLD -80.0dB to 0.0dB Threshold of low band
LOW RATIO 1.0:1 to 20.0:1 Ratio of low band
LOW ATTACK 0.1 to 120ms Attack time of low band
LOW RELEASE 5 to 1000ms Release time of low band
LOW COMP IN ON, OFF Switches the compressor of low band on/off
LOW CUE ON ON, OFF
If this is on, the low band signal will be sent to the CUE bus for
monitoring.
LOW MID GAIN -18.0dB to 12.0dB Low mid band gain
LOW MID
THRESHOLD
-80.0dB to 0.0dB Threshold of low mid band
LOW MID RATIO 1.0:1 to 20.0:1 Ratio of low mid band
LOW MID ATTACK 0.1ms to 120ms Attack time of low mid band
LOW MID RELEASE 5ms to 1000ms Release time of low mid band
LOW MID COMP IN ON, OFF Switches the compressor of low mid band on/off
LOW MID CUE ON ON, OFF
If this is on, the low mid band signal will be sent to the CUE bus
for monitoring.
HIGH MID GAIN -18.0dB to 12.0dB High mid band gain
HIGH MID
THRESHOLD
-80.0dB to 0.0dB Threshold of high mid band
HIGH MID RATIO 1.0:1 to 20.0:1 Ratio of high mid band
HIGH MID ATTACK 0.1ms to 120ms Attack time of high mid band
HIGH MID RELEASE 5ms to 1000ms Release time of high mid band
HIGH MID COMP IN ON, OFF Switches the compressor of high mid band on/off
HIGH MID CUE ON ON, OFF
If this is on, the high mid band signal will be sent to the CUE
bus for monitoring.
HIGH GAIN -18.0dB to 12.0dB High band gain
HIGH THRESHOLD -80.0dB to 0.0dB Threshold of high band
HIGH RATIO 1.0:1 to 20.0:1 Ratio of high band
HIGH ATTACK 0.1ms to 120ms Attack time of high band
HIGH RELEASE 5ms to 1000ms Release time of high band
HIGH COMP IN ON, OFF Switches the compressor of high band on/off
HIGH CUE ON ON, OFF
If this is on, the high band signal will be sent to the CUE bus for
monitoring.
MASTER GAIN -18.0dB to 12.0dB Master gain
KNEE HARD, 1, 2, 3, SOFT Knee of compressor
FLAVOUR VCA, OPTO Compressor type
HARMONICS ON, OFF Switches the harmonics on/off
LINK GAIN - Links and controls the gain of the four bands
LINK THRESHOLD - Links and controls the threshold of the four bands
LINK RATIO - Links and controls the ratio of the four bands
LINK ATTACK - Links and controls the attack time of the four bands
LINK RELEASE - Links and controls the release time of the four bands
Parameter Range Description
Group a, b, c Channel control field group
Override OFF, ON Turns on/off overriding of the channel control field
ChMode man, auto, mute Channel control field mode (man/auto/mute)
ChModePreset man, auto, mute Preset setting of the channel control field
Weight -100 to 15
Relative sensitivity among input channels in the channel
control field
MeterType gain, input, output Meter type of the master field
MasterOverride OFF, ON Turns on/off overriding of the master field
MasterMute OFF, ON Turns on/off the mute setting of the master field
Gain 0 to 127
Automixer gain displayed for each channel when the meter
button of the master field is set to “gain”
InputLevel 0 to 127
Input level displayed for each channel when the meter button
of the master field is set to “input”
OutputLevel 0 to 127
Output level displayed for each channel when the meter
button of the master field is set to “output”
PostWeightingFilter 0 to 127 Level indicator of the channel control field
Parameter Range Description