User Manual
Table Of Contents
- Welcome
- Accessories
- About the accessory disk
- S90 XS/S70 XS Main Features
- About this Manual
- Contents
- Controls and Functions
- Setting Up
- Start Guide
- Modes
- Basic Instructions
- Playing the Keyboard in the Voice mode
- Creating a New Performance by Using Your Favorite Voice (Performance Creator)
- Playing the Keyboard in the Performance Mode
- Singing with a Connected Microphone
- Recording/Playing Back with a USB Storage Device (Audio Record/Play Mode)
- Using a Connected Computer
- Playing the Keyboard Along with Playback of the MIDI File
- Using as a Master Keyboard (Master Mode)
- Making Global System Settings (Utility Mode)
- Saving/Loading Data (File Mode)
- Appendix
- Display Messages
- Troubleshooting
- No Sound
- No sound from the MIC INPUT jack
- Split does not work via the external MIDI device
- Playback continues without stopping
- The sound is distorted
- Sound is cut off
- Only one note sounds at a time
- Wrong pitch or unexpected pitch
- No effect is applied
- Vocoder does not work when selecting a Vocoder Voice
- The Edit Indicator appears, even when parameters are not being edited
- Cannot start the Arpeggio
- Cannot stop the Arpeggio
- The Voice assigned to the Performance produces a different sound from the one in the Voice mode
- Data communication between the computer and the S90 XS/S70 XS does not work properly
- The S90 XS/S70 XS does not sound properly even when playing back the song data on the computer or the MIDI instrument connected to the S90 XS/S70 XS
- MIDI bulk data transmission/reception does not work properly
- Cannot save data to the external USB storage device
- Cannot play an audio file
- Cannot enter the Edit mode
- Specifications
- Index
S90 XS/S70 XS Owner’s Manual
57
Troubleshooting
MIDI bulk data transmission/reception does not work properly
Is the Receive Bulk parameter set to off?
Set the Receive Bulk parameter to on.
If the data was saved with the Bulk Dump function of the S90 XS/S70 XS, you need to set the Device Number to
the same number before Bulk Dump transmission.
When transmission does not work properly, is the device number of the MIDI instrument connected to the S90
XS/S70 XS set to match the Device Number Parameter in the Utility mode?
Cannot save data to the external USB storage device
Is the USB storage device being used write protected? (Write-protect should be set to off for saving data.)
Is the USB storage device being used properly formatted?
Cannot play an audio file
Is the format of the audio file correct?
The S90 XS/S70 XS can play only stereo WAVE (.wav)/AIFF (.aif) files at 44.1kHz/16-bit.
Cannot enter the Edit mode
Is the S90 XS/S70 XS in the File mode?
After exiting from the File mode, press the [EDIT] button.
[UTILITY] [MIDI] Receive Bulk
[UTILITY] [MIDI] Device No.
[UTILITY] [MIDI] Device No.
[FILE] Save Selecting USB storage device [JOB] FORMAT