Troubleshooting
The S90 XS/S70 XS does not sound properly even when playing back the
song data on the computer or the MIDI instrument connected to the S90
XS/S70 XS
Is the S90 XS/S70 XS set to the Multi mode?
Select the Multi mode to play multiple channels simultaneously.
MIDI bulk data transmission/reception does not work properly
Is the Receive Bulk parameter set to off?
Set the Receive Bulk parameter to on.
[UTILITY] [MIDI] Receive Bulk (page 138)
If the data was saved with the Bulk Dump function of the S90 XS/S70 XS, you need to
set the Device Number to the same number before Bulk Dump transmission.
[UTILITY] [MIDI] Device No. (page 138)
When transmission does not work properly, is the device number of the MIDI
instrument connected to the S90 XS/S70 XS set to match the Device Number Parameter
in the Utility mode?
[UTILITY] [MIDI] Device No. (page 138)
Cannot save data to the external USB storage device
Is the USB storage device being used write protected? (Write-protect should be set to
off for saving data.)
Is the USB storage device being used properly formatted?
[FILE] Save Selecting USB storage device [JOB] FORMAT (page 130)
Cannot play an audio file
Is the format of the audio file correct?
The S90 XS/S70 XS can play only stereo WAVE (.wave)/IFF (.aif) files at 44.1kHz/16-bit.
Cannot enter the Edit mode
Is the S90 XS/S70 XS in the File mode?
After exiting from the File mode, press the [EDIT] button.