User Manual

MIDIデータフォーマット
SC2 MIDIリファレンス 11
System Exclusive Messages (1)
*ReceiveSystemExclusiveMessageの設定がOFFのときには受信しません。
*TransmitSystemExclusiveMessageの設定がOFFのときには送信しません。
システムエクスクルーシブメッセージ(ニバーサルリアルタイムメッセージ)
適用範囲 MIDI,本体シーケンサー
MIDI Event
データフォーマット MIDI規格
MIDI受信 MIDI送信
Song
Panel
(主な出力方法)
Song
Master Volume F0 7F XN 04 01 SS TT F7
11110000 F0 = Exclusive status
01111111 7F = Universal Real Time
0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored
00000100 04 = Sub-ID #1=Device Control Message
00000001 01 = Sub-ID #2=Master Volume
0sssssss SS = Volume LSB
0ttttttt TT = Volume MSB
11110111 F7 = End of Exclusive
[GM2] O X
*1
Master Fine Tuning F0 7F XN 04 03 SS TT F7
11110000 F0 = Exclusive status
01111111 7F = Universal Real Time
0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored
00000100 04 = Sub-ID #1=Device Control Message
00000011 03 = Sub-ID #2=Master Fine Tuning
0sssssss SS = Fine Tuning LSB
0ttttttt TT = Fine Tuning MSB
11110111 F7 = End of Exclusive
[GM2] O X
*1
Master Coarse Tuning F0 7F XN 04 04 00 TT F7
11110000 F0 = Exclusive status
01111111 7F = Universal Real Time
0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored
00000100 04 = Sub-ID #1=Device Control Message
00000100 04 = Sub-ID #2=Master Coarse Tuning
00000000 00
0ttttttt TT = Coarse Tuning MSB
11110111 F7 = End of Exclusive
[GM2] O X
*1
Reverb Parameter F0 7F XN 04 05 01 01 01 01 01 PP VV … F7
11110000 F0 = Exclusive status
01111111 7F = Universal Real Time
0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored
00000100 04 = Sub-ID #1=Device Control Message
00000101 05 = Sub-ID #2=Global Parameter Control
00000001 01 = Slot path length = 1
00000001 01 = Parameter ID width = 1
00000001 01 = Value width = 1
00000001 01 = Slot path MSB = 1 (Reverb)
00000001 01 = Slot path LSB = 1
0ppppppp PP = Parameter to be controlled.
0vvvvvvv VV = Value for the Parameter.
……
11110111 F7 = End of Exclusive
Parameter (pp) Value (vv) Display
----------------------------------------------------------------------------
pp=0 Reverb Type 0…8 0: RoomS
1: RoomM
2: RoomL
3: HallM
4: HallL (default)
8: GM Plate
pp=1 Reverb Time 0…127 0…11.0s
[GM2] O X
*1
Chorus Parameter F0 7F XN 04 05 01 01 01 01 02 PP VV … F7
11110000 F0 = Exclusive status
01111111 7F = Universal Real Time
0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored
00000100 04 = Sub-ID #1=Device Control Message
00000101 05 = Sub-ID #2=Global Parameter Control
00000001 01 = Slot path length = 1
00000001 01 = Parameter ID width = 1
00000001 01 = Value width = 1
00000001 01 = Slot path MSB = 1 (Chorus)
00000010 02 = Slot path LSB = 2
0ppppppp PP = Parameter to be controlled.
0vvvvvvv VV = Value for the Parameter.
……
11110111 F7 = End of Exclusive
Parameter (pp) Value (vv) Display
--------------------------------------------------------------------------------------
pp=0 Chorus Type 0…5 0: GM Chorus1
1: GM Chorus2
2: GM Chorus3 (default)
3: GM Chorus4
4: FB Chorus
5: GM Flanger
pp=1 Mod Rate 0…127 0…15.5Hz
pp=2 Mod Depth 0…127
pp=3 Feedback 0…127
pp=4 Send to Reverb 0…127
[GM2] O X
*1