User Manual

RMio64-D Owner’s Manual
16
Syncing the unit to a MADI input signal
NOTE
If the unit acts as the clock slave on the Dante network, input to
the unit the same MADI clock used for the device that is the
clock master. You can use Dante Controller (available from the
following website) to check which device is the current clock
master.
http://www.yamahaproaudio.com/
Using an external clock on MADI-compatible
devices, and syncing the unit to a different
external clock:
NOTE
The same external clock supplied to MADI-compatible
devices must be input to [WCLK IN FOR SRC] on the unit.
If the unit acts as the clock slave on the Dante network, input
to the unit the same external clock used for the device that is
the clock master. You can use Dante Controller (available
from the following website) to check which device is the
current clock master.
http://www.yamahaproaudio.com/
Displaying the MADI Input
and Output Signals
The frame format and number of channels for the MADI
input signal or output signal are displayed in the MADI
[STATUS] area.
Use the MADI [STATUS] INPUT/OUTPUT key to switch
between the input signal display and the output signal
display.
Remote Control
You can use the RMio64-D remote control to configure
items that cannot be configured from the unit’s panel,
such as individual settings for MADI SRC input/output
controls and setting the MADI output to a different format
than the MADI input.
NOTE
For the latest information about remote control compatible
devices, refer to the Yamaha Pro Audio website:
http://www.yamahaproaudio.com/
Remote Controllable
Parameters
Control from NUAGE
Workgroup Manager
When RMio64-D is operating in the NUAGE Workgroup,
you can use remote control to configure the RMio64-D
and use direct monitoring functions.
Word Clock Source Input Clock Source Output Clock Source
DANTE
MADI
WCLK IN
DANTE MADI
Clock
WCLK IN
(FOR SRC)
MADI IN
Same as
Input Clock Source
Same as Word
Clock Source
Signal Processing
Signal
SRC
SRC
Word Clock Source Input Clock Source Output Clock Source
DANTE
MADI
WCLK IN
DANTE MADI
Clock
WCLK IN
(FOR SRC)
MADI IN
Same as
Input Clock Source
Same as Word
Clock Source
Signal Processing
Signal
SRC
SRC
Parameter Description
SRC ON/OFF Turns MADI SRC on or off.
SRC INPUT CLOCK
SOURCE
For selecting the MADI SRC clock
source: the MADI input signal or the
clock input from the WCLK IN FOR
SRC connector.
SRC OUTPUT
CLOCK SOURCE
For selecting the MADI SRC clock
output: the input signal or the unit’s
master clock.
INPUT RATE Displays the frequency when the
MADI input signal is automatically
detected as 44.1 kHz or 48 kHz.
For selecting 1Fs, 2Fs, or 4Fs in
combination with the MADI input
rate.
STATUS INPUT Displays the status of the MADI input
signal.
STATUS OUTPUT Displays the status of the MADI
output signal. You can also make
changes to the frame format and
number of channels for the MADI
output signal.
BNC AES/EBU OUT For selecting the Dante input
channel output from the [SYSTEM
LINK OUT] connector as the AES/
EBU signal.
CLOCK For selecting the source used as the
master clock.
PANEL LOCK Locks the panel to prevent operation
of the unit’s controllers. Default
settings are turned off.