103 Error The power supply has been shut
down by the protection circuit.
Because a high-load situation has
continued, you should lower the
output level. Refer to the owner’s
manual for the reason that
protection was activated.
Continuing
104 Error The protection circuit has activated,
and output [ch*] is muted.
Continuing
105 Fault The output was muted because a
short was detected in speaker
output jack [ch*].
It may be that the + and - of the
speaker output jack have shorted, or
that the connected speaker has
malfunctioned.
Single
106 Warning The temperature of the amp section
(heat sink) has changed, causing
the following speaker output status.
(*)
* = 0dB and OK
-1dB and in protection
muted and in protection
Lower the output level, since
continuous high wattage output will
cause high temperatures. If the
temperature is still high, check
whether dust or foreign matter
might be clogging the cooling fan
intake, and clean the intake if
necessary.
Single
Device information
200 Information The power has turned on. Single
201 Information The power has turned off. Single
202 Information Firmware update has been
completed.
Single
203 Information Initialization has been executed. Single
204 Information Panel lock has been defeated. Single
205 Information The IP address has been
established.
Single
206 Information The network IP address has been
allocated while operating with the
DHCP server.
Single
207 Information The network IP address has been
released while operating with the
DHCP server.
Single
211 Information Synchronization between the Editor
and the devices has begun.
Single
Amp information
102 Information The protection circuit has caused
the limiter [ch*] to operate.
Because a high-load situation has
continued, you should lower the
output level. Refer to the owner’s
manual for the reason that
protection was activated.
Continuing
110 Error The Redundant Backup function has
operated, and channel * has
switched to analog input.
There is a problem with the digital
signal. Check the connection of the
digital circuit, and check whether a
pilot tone signal is being input.
Continuing
17. Power Amplifiers : XMV-series